The range offers iron vane and moving coil ac and dc ammeters and voltmeters. Moving coil instrument working principle your electrical. Moving coil, moving iron and dynamometer type instruments. Construction of pmmc instruments the constructional features of this instrument are shown in fig.
Moving coil instruments electrical technology youtube. The electromagnet is the temporary magnet whose magnetic field strength increases or. The spindle is supported between the jewel bearings. Moving coil instruments there are two types of moving coil instruments namely, permanent magnet moving coil type which can only be used for direct current, voltage measurements and the dynamometer type which can be used on either direct or alternating current, voltage measurements.
The controlling torque is provided by gravity control method while damping torque is provided by air friction as shown in the figure. For low voltage range the power consumption is higher. Moving iron instruments are generally used to measure alternating pdf u3d vulnerability voltages and currents. We know that in moving coil instruments the deflecting torque is given by the expression. Differences between moving coil mc and moving iron mi.
Instrument is low cost compared to moving coil instrument. A scale, b their range, c pointer, d size of terminals, e, leave your comments or download. Jul 25, 2018 theory of attraction type moving iron instrument. Moving iron instruments principle, operation and type. Permanent magnet moving coil or pmmc instrument definition. In this article all major differences between moving iron and moving coil instruments are discussed. They are used as wattmeters,varmeters and with some modification as power factor meters and frequency meters. In this page you can learn various important moving iron instrument multiple choice questions answers,mcq on moving iron instrument with answers,mcq on moving iron instrument,sloved moving iron instrument objective questions answers etc. Alternating current instruments ac page 45 moving iron instruments page 45 moving coil instruments with rectifier page 49 volt ammeter with switch page 4 maximun demand indicators page 415 triple quadruple instruments page 417 power power factor meter page 421 phase sequence indicators page 428 frequency instruments page 429. Since the stationary parts and the moving parts of the instrument are simple so they are cheapest. The moving system of the instrument is attached to the soft iron piece and thus moves the pointer over the scale. Let us have a comparison between two major type of electrical measuring instruments they are moving coil mc and moving iron mi instruments. In this article, we shall study principle, construction, working, sensitivity and accuracy of the moving coil galvanometer. For more details about permanent magnet moving coil instruments click here.
Permanent magnet moving coil instruments advantages. A moving iron ammeter may be compensated for frequency errors by a. Pdf eec 126 instrumentation theory farouq osuolale. Moving coil instrument, having coil resistance of 4. The coil has connections at either end so you can pass an electric current through it and it has a long pointer stuck to it that runs out across the meter dial. In case of moving coil the coil wounded to the soft iron deflects with respect to the torque produced due to the voltage or current in case of moving iron the soft iron would deflect with respect to the torque produced due to. Voltage rated value standard measuring ranges rated value. Disadvantages are due to friction at the bearings and temperature variations, errors are likely to be presentand the observed readings are may not be accurate and fresh. General theory permanent magnet moving coil pmmc instruments 57.
Moving coil and moving iron principles free download as powerpoint. Download as pptx, pdf, txt or read online from scribd. These instruments are based on the principle that when an unmagnetised soft iron piece is placed in the magnetic field of a coil, then the piece is attracted towards the coil. Both moving coil and moving iron instruments are used measure the voltage and current of circuits. The electromagnet is the temporary magnet whose magnetic field strength increases or decreases with the magnitude of the current passes through it. Permanent magnet moving coil mechanism pmmc mathematical. The coil is mounted on rectangular aluminum former, which is pivoted on jeweled bearings. Oct 21, 2016 before answering your question let me explain the working principle of both moving coil and moving iron instruments that will give you a basic idea. Suitable for low frequency and high power circuits.
When a current carrying coil is placed in the magnetic field produced by permanent magnet, the coil experiences a force and moves. The pmmc stands for permanent magnet moving coil and it is also called as darsonval instruments. It is one of the simple and most used instrument on board with sophisticated names. Measurements and instrumentation questions and answers pdf 26. Moving iron instruments principle and operation repulsion type. A permanent magnet is used to produce magnetic flux and a coil that carries the current to be measured moves in this field. Since 1948 ortofon has introduced more then 100 different moving coil models, with our latest being the mc century. Moving iron instruments principle, operation and type, theory of. Oct 14, 2017 moving coil instruments electrical technology duration. To understand the basic construction of a permanent magnet moving coil. Advantages are, moving coil instruments consume quite less power.
Whereas in moving coil instrument the conductor coil is used for dc measurement. What is permanent magnet moving coil or pmmc instrument. They are used on board to assist in regular maintenance of electrical equipment or when precise measurements are required. The iron van is so situated that it can move in the magnetic field produced by a stationary coil. Texas instruments plans to build up inventory as uncertainty looms. This is because the resistance of moving coil is small. Under the action of this torque, the coil rotates and the deflection in the coil in a moving coil galvanometer is directly.
The coil moving coil is a flat disc which is eccentrically mounted on the spindle. Capable of giving an accuracy within limits of both precision and industrial grades. In moving iron instruments, a van of soft iron forms the moving element of the system. May 12, 2018 permanent magnet moving coil or pmmc instruments are the most accurate type for the measurement of dc current or voltage. It is an instrument for detecting and measuring electric current. Dec 30, 2019 in this article, we shall study principle, construction, working, sensitivity and accuracy of the moving coil galvanometer. This iron tends to move inward that is from weaker magnetic field to stronger magnetic field when current flowing through the coil. The coils move freely in the field of a permanent magnet.
A moving iron instruments consists of a stationary hollow cylindrical coil. This type of meter responds to both direct and alternating currents as opposed to the moving coil ammeter, which works on direct current. To see other topics in basic electrical and electronics engineering click here. Movingcoil instrument article about movingcoil instrument. Measurement and instruments objective questions and answers pdf free download. Before answering your question let me explain the working principle of both moving coil and moving iron instruments that will give you a basic idea. View and download powerpoint presentations on moving iron instruments ppt. Aug 18, 20 construction of pmmc instruments the constructional features of this instrument are shown in fig. A soft iron yoke y is used to complete the flux path and to provide shielding from stray external fields. This type of meter responds to both direct and alternating currents as opposed to the moving coil ammeter, which works on. It consists of permanent horseshoe magnets, coil, soft iron core, pivoted spring, nonmetallic frame, scale, and pointer. The moving coil type has the pen attached to a coil carrying current and so behaves like a magnet whose strength is proportional to the current. The basic dc meter movement is known as the darsonval meter movement. The instrument can be constructed to measure current and voltage to an accuracy needed in most engineering works and still be ch.
I instrument the most common ammeter and voltmeter for laboratory or switch board use at power frequency are the moving iron instruments. Moving iron instruments attraction type and repulsion type complete concept duration. A moving coil meter is a very commonly used form of analogue voltmeter because of its sensitivity, accuracy, and linear scale, although it only responds to d. T d nbldi where n is number of turns, b is magnetic flux density in air gap, l is the length of moving coil, d is the width of the moving coil. In movingiron instruments the movable system consists of one or more pieces of speciallyshaped soft iron, which are so pivoted as to be acted upon by the magnetic field produced by the current in coil. Moving coil instruments are supplied with pivot and jewel movements, moving iron with sapphire jewels and bearings together with carbon steel pivots. Types of electrical and electronic measuring instruments a ammeter b moving iron c moving coil d voltmeter e. The teme range is comprised of four instruments, each of which has three movement options. Moving coil and moving iron principles inductor loudspeaker. Jan 15, 2019 let us derive a general expression for torque in permanent magnet moving coil instruments or pmmc instruments. Basic principle operation of moving iron instruments 61. When a currentcarrying coil is suspended in a uniform magnetic field it is acted upon by a torque. Permanent magnet moving coil instruments pmmc the permanent magnet moving coil instruments are most accurate type for direct current measurements. If metallic former is used, then it would induce eddy currents in it.
Advantages and disadvantages moving coil instruments advantages. What is the difference between movingiron and movingcoil. The moving system of the instrument is attached to the soft iron piece and the operating current is passed through a coil placed near it. The scale of permanent magnet moving coil instrument is uniform. One of the most accurate type of instrument used for d. The moving coil is wound either as a selfsustaining coil or else on a nonmetallic former. Movingiron cartridges are pretty much the same as moving.
Working principle and construction of pmmc polytechnic hub. Moving coil instruments are more accurate and reliable as compared to moving iron because they have no hysteresis loss and they are not affected by stray magnetic fields. Jan 27, 2018 2 cost of these instruments is high as compared to moving iron instruments. The first ortofon cartridge, the mc monoa cartridge was developed by holger christian arenstein in 1948. Moving iron instruments construction and basic principle operation in moving iron instruments the movable system consists of one or more pieces of speciallyshaped soft iron, which are so pivoted as to be acted upon by the magnetic field produced by the current in coil. Mar 16, 2018 pmmc stands for permanent magnet moving coil. Moving iron instruments are less sensitive as compared to the moving coil. Home electrical articles comparison between moving iron m. Suppose when there is no current through the coil, the pointer is at zero, the angle made by the axis of the iron disc with the line perpendicular to the field is now due current i and corresponding magnetic field strength, the iron piece is deflected to an angle now component of h in. Moving coil instruments electrical technology duration. The coil is flat and has a narrow slot like opening the moving iron disc or a sector.
In moving iron instruments the movable system consists of one or more pieces of speciallyshaped soft iron, which are so pivoted as to be acted upon by the magnetic field produced by the current in coil. The moving coil is wound with many turns of enameled or silk covered copper wire. Whats the difference between moving magnet, coil, and iron cartridges for turntables. The range offers iron vane and moving coil ac and dc ammeters and voltmeters, elapsed time and frequency meters. Moving iron instruments can be used a to measure dc currents only b to measure ac currents only c to measure a. The movingiron meter was invented by austrian engineer friedrich drexler in 1884. Whats the difference between moving magnet, coil, and iron. Advantages and disadvantages of movingiron instruments. Dec 17, 2015 whats the difference between moving magnet, coil, and iron cartridges for turntables. Deflection torque is proportional to the square of the current.
Benchmark instruments uk teme range of moving coil and. Moving coil and moving iron type instruments can be distinguished by looking at, options are. Attraction type moving iron instruments, moving iron instruments. Moving coil meter an overview sciencedirect topics. Moving coil instruments 39018 there are two types of moving coil instruments namely, permanent magnet moving coil type which can only be used for direct current, voltage measurements and the dynamometer type which can be used on either direct or alternating current, voltage measurements. The permanent magnet moving coil instruments are most accurate type for direct current measurements. The moving iron instruments use the stationary coil of copper or aluminium wire which. The moving iron instrument uses the stationary coil as an electromagnet. Moving coil instrument working principle your electrical guide. Moving coil galvanometer is an electromagnetic device that can measure small values of current. One of the most accurate instruments used for both ac and dc measurement is moving iron instrument. The working principle of pmmc instruments are same as that of darsonaval type of galvanometer, difference being that a direct reading instrument is provided with pointer and scale. Whereas in moving coil instrument the conductor coil is.
The moving iron meter was invented by austrian engineer friedrich drexler in 1884. Click here to download the pdf of this topic permanent magnet moving coil instruments. The moving iron fixed to the spindle is kept near the hollow fixed coil fig. Moving iron instruments are generally used to measure alternating voltages and currents. Let us derive a general expression for torque in permanent magnet moving coil instruments or pmmc instruments. Moving iron mi instruments generally used to measure ac current or voltage but can measure dc current and voltage without any external circuit pointer is connected to specially designed soft iron that moves according to the intensity of magnetic field acting on it the magnetic field is produced by current carrying coil.
Click here to download the pdf of this topic moving iron instruments. Any instrument in which current is sent through one or more coils suspended or pivoted in a magnetic field, and the motion of the coils is used to measure. Advantages and disadvantages of moving coil instruments. The internal construction of moving coil instruments. Watch the video animation to understand quickly the working of a moving coil instruments. Permanent magnet moving coil or pmmc instruments are the most accurate type for the measurement of dc current or voltage. This will give a wrong direction of rotation thus the instrument cannot be used on ac, permanent magnet moving coil instruments can be used for the measurement of dc only. The action of these instruments is based on the motoring principle. Moving iron instrument multiple choice questions mcq and. Nov 02, 2019 its the basic science behind moving coil meters. Electrodynamometer type instruments construction and. Pmmc instruments construction and working principle. The spindle carries pointer which moves over a graduated scale.
One iron vane is held fixed to the coil frame and other is free to rotate, carrying with it. Construction o f the attraction type instrument it consist of fixed coil c and moving iron piece d. An oval shaped soft iron piece is mounted eccentrically to the spindle to which a pointer needle is attached. Impetus gurukul physics vivek phalke 65,092 views 59.
As shown in above diagram, whatever be the direction of current through the coil, the iron piece would always be magnetized in such a way that it is pulled inwards and that is why moving iron instruments can be used for both ac and dc. Attraction type moving iron instruments the principle is when an non magnetized soft iron piece is placed in the magnetic field of the coil. When you go for viva or interview most often question on electrical measurements is what is the difference between mi and mc type instruments. Working principle of moving iron instruments electrical.